m&h infrared probes are touch trigger probes. When approaching a workpiece surface, the stylus deflects and a trigger signal is transmitted to the receiver by infrared light. Interference-free signal transmission between probe and receiver is absolutely vital for process-reliable measuring on machine tools. HDR (High Data Rate) technology avoids interference caused by ambient light from outside and inside the machining area. On the one hand we use the 75 Hz transmission frequency which is different from worldwide line frequencies of 50 Hz or 60 Hz, respectively. On the other hand, an extremely high data rate of 9600 light pulses/sec prevents interference from pulsing machine lamps. Adjustable transmitting power and large transmitting angles go without saying for m&h touch probes. Large receiving angles and microprocessor-controlled evaluation of receiving signals give an absolutely perfect infrared light transmission.
Modular construction - Touch probe can be extended almost without limit
- Slim diameter of measuring mechanism and extensions (Ø 25 mm)
- Extensions with lengths of 30 mm, 50 mm, 100 mm, and 200 mm can be combined
- Measure deep inside the workpiece
- Measure near walls
Freely adjustable trigger force
- Allows measuring of thin-walled workpieces
- Measuring with large cross probes possible
- Adaptation to machine characteristics, e.g. in case of vibrations
Activation of touch probe
- Reliable and unambiguous activation mechanisms ensure a smooth measuring procedure
- The touch probe is automatically activated in the spindle and deactivated in the tool magazine
- Switch-on method AZ – activation of touch probe through pullstud (patented)
- Switch-on method HSK – automatic activation in the spindle through mechanics in HSK shank
- Switch-on method WS – activation through inner coolant or spindle air-blow (patented)
Operation suitable for the workshop
- Quick battery replacement without tool
- Easy, lateral run-out adjustment
- Easy exchange of stylus
Sturdy and well protected
- Glass ring for protection of infrared diodes
- Screw-in break shaft
- Double membrane sealing
- Chip guard shield
- Casing made of stainless steel
- Water-proof probe sealing using IP68 standard